Campuses:
This shows you the differences between two versions of the page.
groups:homestake:meetings:20131114 [2013/11/13 23:50] – created mandic | groups:homestake:meetings:20131114 [2013/11/14 11:38] (current) – mandic | ||
---|---|---|---|
Line 1: | Line 1: | ||
Homestake Telecon, 11/14/2013 | Homestake Telecon, 11/14/2013 | ||
- | Attending: | + | Attending: |
- | 0) Homestake wiki ready to use (?) | + | 0) Homestake wiki ready to use, everyone should check that they have read/write access to it. |
https:// | https:// | ||
Line 10: | Line 10: | ||
1) Status at Homestake (Vuk, Victor, Tanner) | 1) Status at Homestake (Vuk, Victor, Tanner) | ||
+ | Discussed the possible locations, described in | ||
+ | |||
+ | https:// | ||
+ | |||
+ | Upshot: several locations of interest at 4850, will try to go for all of them, although some of them are near active places, such as the Davis campus. At 4100, one location is simple (Bill' | ||
+ | |||
+ | Vuk to send coordinates to Gary, so that he can look at the possible surface locations. | ||
+ | |||
+ | Vuk: would it be possible to operate the stations off of batteries? What are the costs, livetimes, duty cycles? If so, this could be a substantial cost saver, compared to running power cables over long distances. | ||
+ | |||
+ | Gary/ | ||
+ | |||
+ | Vuk/Victor: could consider buying ~100 batteries for ~$10k, which should allow us to operate all our underground stations for 6 months before recharging... | ||
+ | |||
+ | Vuk: will check with SURF whether there are any restrictions regarding the use of batteries underground, | ||
+ | |||
+ | Vuk: need to deal with the GPS/timing issue, which will likely also require additional equipment and a power source. | ||
+ | |||
+ | We did not have time to address the remaining items on the agenda. | ||
+ | |||
2) PASSCAL communications (Vuk, Gary) | 2) PASSCAL communications (Vuk, Gary) |